色综合另类小说图片区,国产AⅤ激情无码久久,久久夜夜免费视频,小舞屈辱打开双腿自慰出白浆

產(chǎn)品詳情

IEC 61215-2:2021地面光伏PV模塊 設(shè)計資格和型式批準測試程序

日期:2024-09-20 10:49
瀏覽次數(shù):179
摘要: IEC 61215-2:2021版本信息 標準號:IEC 61215-2 ED. 2.0 B:2021 適用行業(yè):光伏材料 中文名:地面光伏 (PV) 模塊 - 設(shè)計資格和型式批準 - 第 2 部分:測試程序 英文名稱:Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 2: Test procedures 發(fā)行日期:STANDARD by International Electrotechnical Commission, 02/24/2021 版本號:2.0 頁數(shù):112 文件大小:1 個文件,...

IEC 61215-2:2021版本信息

標準號:IEC 61215-2 ED. 2.0 B:2021

適用行業(yè):光伏材料

中文名:地面光伏 (PV) 模塊 - 設(shè)計資格和型式批準 - 第 2 部分:測試程序

英文名稱:Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 2: Test procedures

發(fā)行日期:STANDARD by International Electrotechnical Commission, 02/24/2021

版本號:2.0

頁數(shù):112

文件大小:1 個文件,5.8 MB

IEC 61215-2:2021簡介

IEC 61215-2 :2021 旨在適用于所有地面平板模塊材料,例如晶體硅模塊類型以及薄膜模塊。該測試序列的目的是確定模塊的電氣和熱特性,并在合理的成本和時間限制內(nèi)盡可能證明該模塊能夠承受在一般露天氣候下的長時間暴露。如此合格的模塊的實際預期壽命將取決于其設(shè)計、環(huán)境和運行條件。

IEC 61215-2:2021重要信息片段

4.10.3 Procedure
a) Measure the irradiance at the proposed module test plane and ensure that at wavelengths between 280 nm and 400 nm it does not exceed 250 W/m2 (i.e. about five times the natural sunlight level) and that it has a uniformity of ±15 % over the test plane.


b) According to the recommendations of 4.10.2e), short-circuit or open-circuit the module.Mount it in the test plane at the location selected in a), normal to the UV irradiance beam.Make sure that the module temperature sensors read (60 ± 5) °C. For flexible modules, the modules shall be mounted per the manufacturer’s documentation with prescribed substrate and adhesive or attachment/mounting means during the test.


c) Subject the module(s) front side to a total UV irradiation of at least 15 kWh/m2 in the wavelength range between 280 nm and 400 nm with at least 3 %, but not more than 10 % in the wavelength band between 280 nm and 320 nm, while maintaining the module temperature within the prescribed range.For bifacial modules repeat the procedure of UV irradiation on the rear-side of the modules.

4.10.3程序

a) 在擬定的模塊測試平面上測量輻照度,并確保在波長介于280 nm和400 nm之間時,輻照度不超過250 W/m2(即約為自然陽光水平的五倍),且在測試平面上的均勻性為±15%。

b) 根據(jù)4.10.2e)中的建議,使模塊短路或開路。將其安裝在測試平面中a)中選擇的位置,垂直于紫外線輻照度光束。確保模塊溫度傳感器讀數(shù)為(60±5)°C。對于柔性模塊,應(yīng)根據(jù)制造商文件,在試驗期間使用規(guī)定的基材和粘合劑或附件/安裝方式安裝模塊。

c) 在280 nm至400 nm的波長范圍內(nèi),使模塊正面受到至少15 kWh/m2的總紫外線照射,在280 nm至320 nm的波長范圍內(nèi),總紫外線照射量至少為3%,但不超過10%,同時將模塊溫度保持在規(guī)定范圍內(nèi)。對于雙面模塊,在模塊背面重復紫外線照射程序。